Abstract
This paper describes the seismic design of Japan Sodium-Cooled Fast Reactor (JSFR), which includes the seismic condition, the seismic isolation system, and the seismic evaluation of the primary components. Since the design seismic loading is set out severely than ever since The Niigata-ken Chuetsu-oki Earthquake in 2007, an advanced seismic isolation system is aimed to reduce the seismic force loaded on the primary components of JSFR to be less than that of the previous seismic isolation system. The advanced seismic isolation system is developed by optimizing the performance based on the previous seismic isolation system considering the natural frequency of the primary components. The laminated rubber bearings thicker than the previous ones and oil dampers are adopted for the advanced seismic isolation system of SFR. The seismic evaluation of nuclear reactor components applying the advanced seismic isolation system is performed and its feasibility is confirmed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.