Abstract

Major earthquakes in urban areas have often been followed by significant fires that cause extensive damage to property. Therefore, a seismic-induced fire is a scenario that should be addressed properly in performance-based engineering. In this paper, numerical and experimental results of welded steel–concrete composite full-strength beam-to-column joints under post-earthquake fires are described. This was part of a European project aimed at developing fundamental data and prequalification design guidelines of ductile and fire-resistant composite beam-to-column joints with concrete-filled tubes. In detail, seismic and fire analyses were used to design moment-resisting frames endowed with the proposed joint typology. A total of six specimens were designed and subjected to both monotonic and cyclic lateral loads. The specimens were subassemblages of beam-to-column joints, and performed well. Since the scope of the project was to promote joint typologies able to survive a seismic-induced fire, some specimens were pre-damaged before being subjected to fire loadings by imposing monotonic loads equivalent to damage levels induced by seismic loadings. Thus, after fire testing, valuable information about the performance of the proposed joint typology was obtained, and the adequacy of the concurrent seismic and fire design was demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.