Abstract

Keywords: Seismic Behavior, Pseudo-dynamic Test, Lateral Cyclic Load, Stiffness Degradation Abstract. The pseudo-dynamic seismic tests and lateral cyclic load tests for tie-columns and ring- beams confined masonry structure according to the seismic requirements and masonry structure strengthened with reinforced concrete beams and columns have been carried out. Cracks propagation pattern, hysteretic curves, skeleton curves and stiffness degradation curves were compared and analyzed. The results from tests show that the brick masonry building with tie- columns and ring-beams has good ductility. The brick masonry building strengthened by RC beam- column can keep bearing capacity after serious cracking of masonry wall. The brick building strengthened by RC beam-column can satisfy the requirements of the seismic fortification criterion. The RC beam and column can be used as reinforcement measure to improve the seismic performance of brick buildings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.