Abstract

Two-way slabs without beams are popular floor systems because of their relatively simple formwork and the potential for shorter story heights. Earthquakes, however, have demonstrated that slab-column frames are vulnerable to brittle punching shear failures in the slab-column connection region and dropping of the slab, which are costly to repair. This paper focuses on the behavior and design of slab-column connections under combined gravity and lateral loading and reviews current design procedures, performance-based design approaches, and relevant experimental data. An equation relating the gravity shear ratio at a slab-column connection to drift capacity is presented. Finally, practical recommendations are provided for defining specific performance objectives.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.