Abstract
Seismic design and qualification of safety and/or radiological relevant structures for Swiss NPPs are subjected to rigorous procedures. Structures have to meet high safety standards, be robustly designed and therefore cover a wide range of parameter uncertainties both on seismic action and capacity side. In the framework of a wide Facility Power Retrofit at the Swiss Leibstadt NPP the Project ZENT (acronym of radioactive waste storage building) aims to erect two new structures on the site. Due to operational and radiological reasons, these new structures have to be built very close respectively above to the already mentioned existing structures. One structure has to be founded on piles above the existing NPP main cooling pipelines. Approval of this new seismic foundation system by Swiss Federal Nuclear Safety Inspectorate (ENSI) required extended seismic design. This paper attempts to describe the analyses performed by the Owner for seismic qualification and verification of structural integrity at planning stage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.