Abstract
The HTR-10, which now is under construction, is the first high-temperature gas-cooled reactor developed in China. The primary loop boundary components of the HTR-10 are peculiarly arranged as the reactor pressure vessel stands side by side with the steam-generator pressure vessel, and a hot-gas duct vessel connects them. This arrangement can diminish the thermal loads on the pressure vessels but can cause some new problems under seismic conditions. The design features of the support system of the HTR-10 primary loop boundary components are introduced. The procedure of seismic analysis of the support system is emphasized. Based on equivalent-static and dynamic calculations, the safety features of the support system under seismic conditions are demonstrated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.