Abstract

ABSTRACT A new damping control method for the adjacent liquid storage tanks (LSTs) based on vibration barrier (ViBa) is proposed. Considering liquid-solid-soil coupling and structure-soil-structure interaction, a three-dimensional numerical calculation model is established by ADINA. The seismic control effect of ViBa is investigated, and parametric analysis is carried out. The results show that ViBa has a significant control effect on seismic responses and wave height, and the reduction factor of base shear force reaches the maximum value of 49.26%. The larger the seismic intensity, the liquid storage height and the height-radius ratio, the larger the reduction factor of the ViBa.