Abstract
The aim of this work is to reach a better understanding of the seismic behaviour of historic three-leaf stone masonry buildings with timber floors, before and after interventions. For this purpose, shaking table tests were performed on a building model (scale 1:2). Initially, the dynamic characteristics of the model were identified. Subsequently, biaxial earthquake tests were performed with the base acceleration increased step-wise until the occurrence of repairable damages. Afterwards, the masonry was strengthened by means of grouting and the diaphragm action of the floors was enhanced. Then, the strengthened model was re-tested. The comparison of the performance of the model under earthquake actions before and after strengthening shows that the selected intervention techniques significantly improved the seismic behaviour of the structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.