Abstract

Previous studies on the connection between concrete-filled steel tube (CFST) columns and reinforced concrete (RC) beams have shown a loss of joint confinement because the steel tube was completely or partially cut in the joint area. This research presents a new connection system that provides joint confinement through a continuous steel tube. Potential sliding shear at the smooth interface between the columns and beams in the joint face is mitigated using two mechanisms: (i) shear connectors and (ii) longitudinal web beam reinforcement. This study tested two CFST column and RC beam joints to 4.5% drift ratio under combined compression axial load and lateral cyclic load. The experimental results revealed no cracks at the joint zone and the specimens satisfied the ACI 374.1-05 criteria, despite minor sliding at the beam-column interface. The finite element (FE) model showed good agreement with the experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.