Abstract
To overcome the problem that steel bars are put too close at a flame joint with special-shaped beam and column, mechanical performance of three groups of six RC flame joints with special-shaped (L, T and +) column and dispersed-steel bars-beam on the top floor under cyclic loads were studied. Experimental comparison was conducted between special-shaped (L, T and +) column and normal beams. The cracking load, yielding load, ultimate bearing capacity, failure patterns, and hysteretic properties at joint core area were investigated. The seismic behaviors of the joints with different proportions of dispersed-steel-bar beams were analyzed. The results of experimental analysis indicate that the mechanical and seismic behaviors of frame joints with T-shaped and +-shaped column are nearly not changed when suitable proportion steel bars are dispersed to flange plane. Stiffness degeneration of flame joint with L-shaped column is rather serious due to concrete damage stiffness. Theoretical result indicates that distributing area of the dispersed steel-bar beams in the flange plate should be strictly controlled to avoid anchor destroy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Frontiers of Architecture and Civil Engineering in China
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.