Abstract
This paper investigates the effects induced by thunderstorm downbursts to steel building structures that have been previously damaged during strong directivity ground motion events. To achieve this objective, one four-story steel moment-resisting frame that was tested at the E-defense laboratory, Japan was analyzed in the nonlinear range using OpenSees. The seismic response was numerically simulated, obtaining a satisfactory agreement with the experimental evidence, revealing that the effects of such wind events and vertical ground motions were significant. These effects should be addressed during the design of low and medium buildings subjected to initial damage and subsequent thunderstorm downbursts and the ductility demands on structures subjected to multi-hazards can be quantified. The wind loads are applied as an externally applied dynamic load and the revised ductility demands are determined directly. The obtained results are compared to what is expected by experimental tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Engineering, Technology & Applied Science Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.