Abstract

This article presents a numerical study for the seismic assessment of a Portuguese building masonry typology - “Gaioleiro.” Numerical analysis was performed using a finite element model calibrated with experimental results obtained in 1:3 reduced scale tests carried out in the LNEC 3D shaking table. Nonlinear dynamic analysis with time integration and pushover analysis are carried out. Using nonlinear dynamic analysis it was verified that the buildings of “Gaioleiro” type with appropriate floor-wall connections are in the limit of their loading capacity. The pushover analyses performed in this study were incapable of simulating correctly the damage of the structure under seismic action.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call