Abstract

This work forms part of a research programme to assess and strengthen existing reinforced concrete (RC) walls that were designed using older seismic codes. The main object of the present paper is to examine the behaviour of concrete shear walls that do not comply with modern seismic codes (Eurocode 2 (EC2) and Eurocode 8 (EC8)) and compare their experimental performance with the provisions for assessment of RC members included in EC8 Part 3. For this purpose, a series of six shear walls (height h = 1·40 m, length l = 0·74 m, thickness b = 0·10 m) was designed and tested under static cyclic loading. The wall specimens were characterised by various types of reinforcement arrangement, focusing on different amounts of shear reinforcement. The issues investigated are the failure modes, ductility level, the absence of confined boundary elements, the low amount of shear reinforcement, the influence of diagonal reinforcement and the influence of axial load. The experimental results are compared with the provisions included in EC8 Part 3, which predict the shear strength, the chord rotation ductility and the effective stiffness of RC shear walls.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.