Abstract
A simplified seismic calculation model of immersed tunnel is built up, which is applied to the seismic analysis of Hong Kong-Zhu Hai-Macao Bridge Project’s immersed tube tunnel. According to different spring stiffness of foundation and different spring stiffness of joint, the tunnel and joint’s force and deformation conditions are compared. The results show that: the influence of foundation spring stiffness is significant, for engineering design, the foundations of a more flexible approach should be preferred; contrary to joint force, the joint opening increases with the increase of joint stiffness, thus, flexible joint is better for project; the connection parts of floor and wall, the connection parts of roof and wall are the most disadvantageous position during the earthquake, so, these parts’ design strength should be strengthened and deformation control should be taken.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.