Abstract

We consider one of the existing technologies, scilicet of the multi-shift safety monitoring, which implies tracking of the integrity of the information system (IS) by periodically replacing each other operators in the interval between diagnostics of the system, in relation to computerized boiler-rooms with network access. Herein the IS of the boiler-house is taken into account as protected from dangerous software-engineering influences through the computer network only if to the beginning of the specified period of time the integrity of the system is ensured and throughout this set period the sources of danger do not penetrate the system (with a calculated probability). Here the operator of the boiler-room figures as an eventual link of the series of the controlled, including the program level, barriers for (external) network malefactor. For computerized boiler-houses, depending on the ratios for the duration of the operator’s work during each shift, the specified period of safe operation and the period between diagnostics, three variants are considered that are typical for this technology. The possibilities of applying the latter in the foreshortening of risk assessment of emergency situations (ES) within the previously developed by the author logical-probabilistic model for computerized boiler-houses are discussed.

Highlights

  • Аннотация Рассматривается одна из существующих технологий — многосменного мониторинга безопасности, подразумевающая отслеживание целостности информационной системы (ИС) периодически сменяющими друг друга операторами в интервал между диагностиками ими системы — применительно к информатизированным котельным с сетевым доступом

  • The information system (IS) of the boiler-house is taken into account as protected from dangerous software-engineering influences through the computer network only if to the beginning of the specified period of time the integrity of the system is ensured and throughout this set period the sources of danger do not penetrate the system

  • For computerized boiler-houses, depending on the ratios for the duration of the operator’s work during each shift, the specified period of safe operation and the period between diagnostics, three variants are considered that are typical for this technology

Read more

Summary

ИЛИ И

Преодоление защитной физической «суммарной» преграды (включая возможное проникновение под видом должностного лица или иного лица либо совместно с ним), с учетом возможности совместимого отказа подсистемы охранной сигнализации и/или контроля доступа (ИС z29). Преодоление защитной (сетевой) «суммарной» компьютерной преграды (включая возможное несанкционированное завладение логином и паролем сотрудника) с учетом возможности совместимого отказа подсистемы защиты информации (ИС z27). 1. Возможный сценарий опасного состояния котельной или иной сущности) одной либо более дублирующих ее преград в многозвенной защите). 1 ИС z31 (саботаж либо ошибки персонала) и для более пристально рассматриваемого в данной статье ИС z27 (преодоление защитной (сетевой) «суммарной» компью­терной преграды (включая возможное несанкционированное завладение логином и паролем сотрудника), с учетом возможности совместимого отказа подсистемы защиты информации): событие z31 подразумевает ошибки 1-го рода, а событие z27 подразумевает ошибки именно 2-го рода.

Предмет защиты
Количество k смен операторов между соседними диагностиками