Abstract

The effectiveness of an operator-initiated steam generator (SG) secondary-side depressurization on the core cooling performance during small-break loss of coolant accidents (SBLOCAs) in a pressurized water reactor (PWR) with total failure of the high pressure injection (HPI) systems is studied. The study is based on experiments conducted in the ROSA-V Large Scale Test Facility (LSTF) and analyses with the RELAP5/Mod3 code. The sensitivity of the core minimum liquid level and peak cladding temperature (PCT) to the secondary-side depressurization rate and the initiation time of the depressurization is evaluated analytically for various break sizes. It is shown that the PCT takes a maximum value for break areas between 1.0% and 1.5% of the cold leg cross-sectional area. The conditions which the depressurization rate and the initiation time should satisfy to limit the maximum PCT are derived.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.