Abstract

SECONDARY CLARIFIER OPERATIONAL TESTING INCREASES FACILITY CAPACITYThe Central Davis County Sewer District (CDCSD) conducted a long-term secondary clarifier stress test to verify that state point analysis accurately predicts clarifier capacity. The stress testing indicated that SPA accurately predicted capacity to a much greater degree than previous research as indicated by the following four criteria:Author(s)David J. KinnearLeland MyersMarko HahnDenny ParkerSourceProceedings of the Water Environment FederationSubjectSession 15 - Plant Operations I: Plant Operations and Maintenance: Clarification and Plant ModelsDocument typeConference PaperPublisherWater Environment FederationPrint publication date Jan, 2001ISSN1938-6478SICI1938-6478(20010101)2001:15L.361;1-DOI10.2175/193864701790902923Volume / Issue2001 / 15Content sourceWEFTECFirst / last page(s)361 - 385Copyright2001Word count167

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call