Abstract

A 73-year-old man underwent coronary artery bypass grafting, abdominal aortic aneurysm resection, and prosthetic implantation as a single procedure in 2002. His progress was favorable until April 2008, when he was admitted to our hospital with melena. B-mode ultrasonography revealed a 5-mm defect in the abdominal aorta at the graft anastomosis, and an umbilicated lesion was seen projecting between the posterior wall of the third part of the duodenum and the abdominal aorta. A color signal was noticed at this site on color Doppler ultrasonography, leading to the diagnosis of a secondary aortoduodenal fistula (ADF). We resected the inflammatory mass comprising the graft and the third part of the duodenum, and performed prosthetic re-implantation, omentopexy, and duodenojejunostomy. We could not find any previous reports of successful identification of secondary ADF using ultrasonography. When a patient with gastrointestinal hemorrhage following reconstructive aortic surgery is encountered in the emergency department, ultrasonography may be considered to be a useful modality in the diagnosis of secondary ADF.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.