Abstract
Background: Although controversy continues over the choice of graft tissue, including autografts, allografts, and synthetic ligaments, for posterior cruciate ligament (PCL) reconstruction, the use of a mixed graft consisting of a hamstring (semitendinosus and gracilis) autograft plus tibialis anterior allograft tendon has not been studied in detail. Hypothesis: Outcomes of PCL reconstructions performed with a mixed graft would be superior to those using solely an Achilles tendon allograft in terms of functional knee scores, posterior stability, and the graft appearance. Study design: Cohort study; Level of evidence, 2. Methods: Fifty-eight patients who underwent isolated single-bundle PCL reconstruction using an arthroscopic trans-septal portal with remnant preservation technique were evaluated. They were divided into group A (mixed tendon; n = 30) and group B (Achilles tendon; n = 28). Knee function was evaluated using the Lysholm knee score, Tegner activity score, and the International Knee Documentation Committee (IKDC) grading scale. Anteroposterior stability was measured using the Telos stress view. Twenty patients (66.7%) from group A and 21 patients (75.0%) from group B underwent hardware removal and a second-look arthroscopic examination. Results: The Lysholm knee scores in groups A and B increased from a respective average of 43 and 50 preoperatively to 90 and 88 at follow-up. The IKDC grade and Tegner activity scores were also significantly improved in both groups. Stability was improved in both groups, with an average posterior laxity of 3.0 mm (group A) and 3.3 mm (group B) at follow-up (P > .05). However, there were 4 intraoperative complications in group B: 2 bone fractures and 2 graft pullouts during precyclic tensioning. Second-look arthroscopy revealed a partial tear in 8 cases (40%) from group A and 15 cases (71.4%) from group B (P = .03). All of the partial tears were located in the femoral aperture area. Complete synovial coverage was demonstrated in 10 patients (50%) from group A and 5 patients (23.8%) from group B (P = .04). However, clinical outcomes and stability were not affected by the arthroscopic graft appearance. Conclusion: Satisfactory results were obtained for groups A and B in patients who underwent reconstruction for isolated PCL injury. However, 4 intraoperative complications (14.3%) were encountered with use of the Achilles tendon allograft (group B), with a relative higher rate of partial tear and less synovialization in the femoral aperture area.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.