Abstract

When a type-II superconductor, exposed to a perpendicular alternating magnetic field, carries a direct current, a biased dc voltage response can occur. The response voltage can be classified into dynamic-resistance voltage and flux flow voltage according to its triggering mechanism. Experimental results for the phase differences of the two types of voltage have been provided in the paper. Harmonic analysis on the voltage response has been carried out to differentiate the two types of the response voltages. Based on analyzing the experimental data, a useful and flexible real-time method using the ratio of the dc component to the second harmonic component of the voltage response has been proposed to serve as a monitor indicating the state of dc-carrying HTS tapes subject to an ac magnetic field. The method is promising in the application of complex superconducting systems such as flux pumps, persistent current switches, superconducting cables and dc fault current limiters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.