Abstract

Second harmonic generation (SHG) pulses at λ ∼ 2.25 µm have been obtained from a 4.5 µm quantum cascade laser (QCL) when it is resonantly pumped by transverse magnetic polarized 120 fs, λ = 4.5 µm pulses through the QCL’s front facet at room temperature. The measured SHG spectrum narrows when the bias across the QCL increases due to the electron population re-distribution and subband realignment. The expected quadratic dependence of the SHG with pump power is observed but saturates at higher pump powers. The linear to nonlinear power conversion efficiency is calculated (∼2 µW/W2) and compared with theoretical calculation. This experiment provides an alternative way of investigating the carrier dynamics in QCLs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.