AbstractThis article proposes a method to effectively suppress second‐harmonic current (SHC) of dual active bridge (DAB) converter, which adopts the triple‐phase shift (TPS) modulation strategy, in two‐stage single‐phase inverter system. Load current feedforward control with twice the output voltage frequency notch filter inserted is introduced to ensure the dynamic response performance. The averaged model of the system is established to analyse the influence of output impedance of front‐end DAB converter on SHC from the perspective of impedance. The proposed method does not need to consider the accuracy of the intermediate bus capacitance. Finally, an experimental prototype was established to verify the correctness and effectiveness of the proposed SHC reduction method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.