Abstract

Assessing medium-term functional results of a novel minimally-invasive treatment for lower urinary tract symptoms due to BPO with the second generation of the temporary implantable nitinol device (iTind; Medi-Tate Ltd®, Israel): 2-year follow-up of a single-arm, prospective, international multicenter study. Further, we aimed to identify preoperative baseline parameters predicting response to iTind treatment. Following local ethical committee approval in every participating centre, 81 men with symptomatic BPO (IPSS ≥ 10, peak urinary flow < 12ml/s, and prostate volume < 75ml) were enrolled in this study. Patients with PVR > 250ml, obstructive median lobe, previous prostatic surgery, confounding bladder or sphincter dysfunction based on medical history, active urinary infection and unable to interrupt antithrombotic or antiplatelet treatment were exclusion criteria. A wash-out period of 1month for alpha-blockers and 6months for 5-ARIs was mandatory to avoid confounders. The procedure was performed as previously described: implantation under light sedation and removal 5-7days later with topical sedation. Patients were assessed for perioperative results including OR-time, pain (VAS) and complications (Clavien-Dindo-Grading System); and for functional results (PVR, Qmax, IPSS) and quality of life (QoL) including sexual and ejaculatory function using two yes/no questions. Follow-up assessments were done at 1, 3, and 6months, and 1 and 2years. Of the 81 patients initially enrolled in this study, follow-up included 67 men at 1year and 51 men at 2years. For the 51 men included in the present analysis, the median age was 65years, median prostate volume 37ml (range 16-65ml). Baseline values for IPSS and QoL were 20.51 ± 4.58, 3.96 ± 0.87. Qmax and PVR were 7.62 ± 2.25ml/s and 65.84 ± 38.46, respectively. No intraoperative complications were observed and the average pain level recorded on the visual analogue scale (VAS) was 3.2 ± 1.6. A significant reduction in symptoms and improvement in urinary flow was observed (p < 0.0001) at all assessment points: IPSS-score and QoL improved to 8.51 ± 5.51 and 1.76 ± 1.32, respectively; and Qmax increased to 16.00 ± 7.43ml/s. None of the patients who were previously sexually active reported a deterioration in sexual or ejaculatory functions according to two yes/no questions over the follow-up period. Excluding the patients lost at follow-up, five patients underwent surgery between 12 and 24months. Upon investigation, it was discovered that four of the five patients requiring surgery had median lobes and were protocol deviators. A failure analysis was carried out for all 81 patients in order to identify baseline parameters that could predict treatment failure. 58.33% of patients in the failure group (7 out of 12) had median lobes which was found to be statistically significant (p < 0.0001). None of the other preoperative variables (age, prostate volume, IPSS scores, Qmax, PVR, and PSA) were found to predict response to iTind treatment. iTind treatment for BPO-related LUTS showed marked and durable reduction in symptoms and improvement of functional parameters and quality of life at 24months of follow-up. It was found that median lobe may predict failure of iTind treatment. According to the yes/no questions, ejaculatory and sexual functions do not seem to be effected following treatment, however, this finding must be supported with further studies using the accepted tools.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.