Insulator missing fault is a serious accident of high-voltage transmission lines, which can cause abnormal energy supply. Recently, a lot of vision-based methods are proposed for detecting an insulator missing fault in aerial images. However, these methods usually lack efficiency and robustness due to the effect of the complex background interferences in the aerial images. More importantly, most of these methods cannot address the insulator multi-fault detection. This paper proposes an unprecedented cascaded model to detect insulator multi-fault in the aerial images to solve the existing challenges. Firstly, a total of 764 images are adopted to create a novel insulator missing faults dataset ‘IMF-detection’. Secondly, a new network is proposed to locate the insulator string from the complex background. Then, the located region that contains the insulator string is set to be an RoI (region of interest) region. Finally, the YOLO-v3 tiny network is trained and then used to detect the insulator missing faults in the RoI region. Experimental results and analysis validate that the proposed method is more efficient and robust than some previous works. Most importantly, the average running time of the proposed method is about 30ms, which demonstrates that it has the potential to be adopted for the on-line detection of insulator missing faults.
Highlights
In the past decades, human demand for electric energy has been increasing with the development of industrial civilization [1]
Based on the above works, we propose an unprecedented cascaded model to detect the insulator missing faults in aerial images
The proposed cascaded model is divided into two parts for a step by step analysis
Summary
Human demand for electric energy has been increasing with the development of industrial civilization [1]. This situation inevitably leads to a phenomenon that many countries have begun to build a large number of high-voltage transmission lines. It is quite important to conduct regular inspections for high-voltage transmission lines. The transmission lines usually span a large geographical area, which causes the traditional human-vision inspection to suffer from high error rates and be time-consuming [8], as shown in the first column of the Figure 1a.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.