Abstract

A new experimental run of searching for double beta decay of 106Cd was performed at the Modane underground laboratory (LSM, France, 4800 m w.e.) using the TGV-2 spectrometer, consisting of 32 planar type HPGe detectors with a total sensitive volume of ~400 cm3. 16 foils of 106Cd with an enrichment of 99.57% and a total mass of ~ 23.2 g were inserted between the entrance windows of face-to-face detectors. The limit on 2vEC/EC decay of 106Cd - T1/2 > 3.7 × 1020 y at 90% C.F was obtained from the preliminary calculation of experimental data accumulated for 8198 h of measurement. The limits on the resonance OvEC/EC decay of 106Cd were obtained from the measurement of ~23.2 g of 106Cd with the low-background HPGe spectrometer Obelix lasted 395 h -T1/2 (KF, 2741 keV) > 0.9 × 1020 y and T1/2 (KK, 2718 keV) > 1.4 × 1020 y at 90% C.L.