Abstract

This article is focused to design of vacuum chamber for deep drawing machine working by high temperatures. The high temperatures are demanding because of use of molybdenum sheet, which should be drawn by temperatures approx. 300 °C. The thermal analysis is important for the correct design of the deep drawing machine for two reasons: The first is the correct temperature of the molded material—molybdenum sheet and the second is the temperature around the seals of vacuum chamber. The simulation forms the basis for selecting the appropriate type of seals. The result of the simulation is a thermal field of working components: the punch, the die, the blank holder, the working plate, and the working table. The second important analysis result is the temperatures of components, which are in contact with seals in particular places.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.