Abstract

Sealing is one of the most successful applications of magnetic fluids. However, the sealing pressure difference is not satisfactory. This paper theoretically analyzes the mechanism of magnetic fluids sealing. Main factors that have significant effects on the sealing ability include viscous stress on the interfacial surface, magnetic surface tension, and the shape of the interfacial surface. The sealing pressure with magnetic fluids decreases with increase of rotational speed. Experiments were carried out to study the stability of the interface between magnetic fluids and water. It has been shown that stability of the interface will be damaged by washing of water when the relative flow between water and magnetic fluid becomes turbulent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.