Abstract
Sixteen kinds of FeCrAl coatings with different Cr and Al contents were prepared by the magnetron sputtering method, and the thermal shock resistance and static lead‑bismuth eutectic (LBE) corrosion behavior (500– 650 °C for 1000 h) were investigated. The results show that the coating with poor thermal shock resistance could also peel off during the corrosion test, and the corrosion resistance of the coating is strongly related to the Cr and Al composition. A relatively high Al content could be required for the FeCrAl coatings to maintain outstanding performance, which is different from the traditional design of the FeCrAl bulk alloys.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.