A high-performance liquid chromatographic (HPLC) method for phenoxy acid herbicides using precolumn derivatization with 9-anthryldiazomethane (ADAM) is presented. The phenoxy acid herbicides investigated were (2,4-dichlorophenoxy)acetic acid, (4-chloro-2-methylphenoxy)acetic acid, 2-(4-chloro-2-methylphenoxy)propionic acid and (4-chloro-2-methylphenoxy)butyric acid. These herbicides reacted with ADAM under mild conditions and were converted into the corresponding fluorescent derivatives. The ADAM derivatives were separated by reversed-phase HPLC and determined using a fluorescence detector. The detecion limits were about 500 pg per injection. For the application of ADAM to the determination of these herbicides in ground waters, the recoveries were more than 93% and the average relative standard deviation was 6.0% at 0.5 μg/l. The procedure is useful as a screening method for phenoxy acid herbicides in ground water samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.