Abstract

Purpose: To evaluate the diagnostic accuracy of a diagnostic system software for the automated screening of diabetic retinopathy (DR) on digital colour fundus photographs, the 2019 Convolutional Neural Network (CNN) model with Inception-V3. Methods: In this cross-sectional study, 295 fundus images were analysed by the CNN model and compared to a panel of ophthalmologists. Images were obtained from a dataset acquired within a screening programme. Diagnostic accuracy measures and respective 95% CI were calculated. Results: The sensitivity and specificity of the CNN model in diagnosing referable DR was 81% (95% CI 66–90%) and 97% (95% CI 95–99%), respectively. Positive predictive value was 86% (95% CI 72–94%) and negative predictive value 96% (95% CI 93–98%). The positive likelihood ratio was 33 (95% CI 15–75) and the negative was 0.20 (95% CI 0.11–0.35). Its clinical impact is demonstrated by the change observed in the pre-test probability of referable DR (assuming a prevalence of 16%) to a post-test probability for a positive test result of 86% and for a negative test result of 4%. Conclusion: A CNN model negative test result safely excludes DR, and its use may significantly reduce the burden of ophthalmologists at reading centres.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.