Abstract

Acyclic guanosine analogues, a class of widely used antiviral drugs, can cause chronic toxicity and virus resistance. Therefore, it is essential to establish rapid and accurate methods to detect acyclic guanosine analogues. In this study, five acyclic guanosine analogues (acyclovir, famciclovir, ganciclovir, penciclovir, and valaciclovir) were used as positive targets to obtain broad-spectrum aptamers through Capture-SELEX technology. Real-time quantitative PCR (Q-PCR) was used to monitor the aptamer SELEX process. After the sixteen rounds of selection against mixed targets, sequences were obtained by high-throughput sequencing (HTS). Furthermore, a broad-spectrum aptamer, named CIV6, was found as the higher performance aptamer that was suitable for five acyclic guanosine analogues by graphene oxide (GO) polarization and fluorescence assay. Finally, the aptamer CIV6 was used to construct GO fluorescence assay to detect five acyclic guanosine analogues. The limits of detection (LOD) of acyclovir, famciclovir, ganciclovir, penciclovir, and valaciclovir were 0.48 ng·mL-1, 0.53 ng·mL-1, 0.50 ng·mL-1, 0.56 ng·mL-1, and 0.38 ng·mL-1, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.