Abstract
This paper presents experimental results for the liquid hydrogen bubble point tests for liquid acquisition devices (LADs) operating in low gravity cryogenic propulsion systems. The purpose of the test was to investigate parameters that affect screen channel LAD performance in a low pressure liquid hydrogen (LH2) propellant tank and to demonstrate several ways to increase the LH2 bubble point pressure. Three fine mesh screen channel LAD samples were tested in LH2 over the range of 16.7 K < T < 21.1 K and 31.5 kPa < P < 155 kPa using gaseous helium and hydrogen as pressurant gases. Results show that bubble point pressure is affected by screen mesh type, liquid temperature and pressure, and type of pressurization gas. Higher bubble points are achieved by using a finer mesh screen and pressurizing and subcooling the liquid with gaseous helium. In addition, there is evidence that the screen pore is itself temperature dependent.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.