Fast wave injection is employed on the DIII-D tokamak as a current drive and electron heating method. Bursts of energetic ions with energy Eo > 20 keV are observed immediately following fast wave injection in experiments featuring the 8th ion cyclotron harmonic near the antenna. Using the energy and pitch angle of the energetic ion burst as measured by a fast-ion loss detector, it is possible to trace the origin of these ions to a particular antenna. The ion trajectories exist entirely within the scrape-off layer. These observations are consistent with the presence of parametric decay instabilities near the antenna strap. It is suggested that the phase space capabilities of the loss detector diagnostic can improve studies of wave injection coupling and efficiency in tokamaks by directly measuring the effects of parametric decay thresholds.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.