Abstract

The X-radiation emission from a low energy plasma focus with argon as a filling gas is investigated. Specifically, the attention is paid to determine the system efficiency for argon K-lines and Cu-K/sub /spl alpha// line emission at different filling pressures, and identify the radiation emission region. The highest argon line emission found at 1.5 mbar is about 30 mJ and the corresponding efficiency is 0.0015%. The same pressure is suitable for high Cu-K/sub /spl alpha// emission, which is about 70 mJ in 4/spl pi/ geometry and the system efficiency is 0.003%. The bulk of X-radiation is emitted from the region close to the anode tip, whereas some radiation emission takes place from the formed hot spots along the focus axis. These radiations are found suitable for backlighting in Al (1-1.56 keV) and Ti (2.9-4.96 keV) energy transmission bands.