Abstract
The scintigraphic findings are described for a patient with severe metallosis in a failed noninfected total knee arthroplasty secondary to metal-metal friction between the femoral and tibial components as a result of polyethylene wear. Technetium-99m phosphate and gallium-67 citrate scans were positive in incongruent uptake areas. This uptake is classifically associated with septic loosening. The recommendation is made that metallosis be suspected before surgery as a possible cause of a false positive scan where sequential technetium-gallium scans are employed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.