Abstract

Evaporative condenser for steam condensing of mini-turbine of steam feeding water pump for 1000 MW air-cooled unit is designed. Variable working condition is analyzed based on the reverse flow between steam and air. The results show that the condensing temperature of the steam in the tube increases with the air temperature and water film temperature increasing. The condensing temperature of the steam decreases with the water flow rate increasing and the wind velocity increasing. The evaporation capacity of the water outside the tube increases with wind velocity increasing. This paper can be refered when evaporation condenser is applied in thermal power plant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.