Abstract

Background Percutaneous endoscopic gastrostomy (PEG) tube insertion is used for enteral nutrition. Each manufacturer has its own instructions for planned tube replacement. Accordingly, caregivers have adopted the policy of elective change at a fixed period of time (3–6 months). Aim The current study aimed to assess whether retained PEG for more than 6 months was associated with a higher rate of PEG-related complications. Methods A retrospective single-center study included all patients who underwent PEG insertion were included in the study. Results Overall, 303 patients were included, 48 patients (16.2%) had PEG tube replacement. Peristomal PEG tube leak was the commonest complication, occurring in 20 patients (41.7%), followed by dislodgement in 18 patients (37.5%) and obstruction in 10 patients (20.8%). Among the patients with a leak, it occurred within and beyond 6 months from PEG insertion in 40 and 60% of patients, respectively (OR 0.68, 95% CI 0.21–2.18, p = .57). Similarly, 50% of patients had PEG tube obstruction within 6 months and 50% had it beyond 6 months from insertion (OR 1.46, 95% CI 0.34–6.26, p = .72). Moreover, there was no difference in PEG dislodgement after PEG insertion within or beyond 6 months (nine patients, 50% vs. nine patients, 50%), respectively, (OR 1.37, 95% CI 0.42–4.47, p = .76). Conclusion Retained PEG tubes for more than 6-months were not associated with more PEG-tube-related complications.