Abstract
Stress corrosion cracking (SCC) behaviour of laser powder bed fused stainless steel 316L was evaluated with U-bend testing in oxygenated high-temperature water at 288 °C. The effects of solution annealing temperature (1066, 1150 and 1200 °C), surface finish (as-built and wire cut) and the sample orientations on the SCC behaviour were studied. The results show that a higher annealing temperature introduces further recrystallization, coarsening of the oxide inclusions and a decrease in resistance to SCC. A wire cut surface leads to a higher susceptibility to SCC than the as-built surface. Sample orientation was found not to affect the SCC susceptibility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.