Abstract

Accurate measurements of α-particle emitting sources with 2π detectors require corrections due to scattering and self-absorption of α-particles from the source and from the backing material. We applied the Monte Carlo computer code SRIM, developed to simulate the transport of ions in matter, to the study of these corrections in the most general case, i.e. to the measurement of α-particle emitters with low specific activity, where the self-absorption effect in the source is considerable. The values of the ratio C 2π/ N 0 (counting rate divided by disintegration rate) were calculated for sources of uranium dioxide containing a mixture of 235U and 234U mounted on a platinum backing, with a wide range of source thicknesses from 0.0 to 1.1 mg/cm 2. The calculated ratios were in agreement with the available experimental data. The work shows that Monte Carlo simulation of the transport of ions by means of the code SRIM can be a very useful tool to evaluate the corrections needed in the measurement of α-particle sources with 2π detectors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.