Abstract

BackgroundTreatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D). Part of 4D treatment planning is calculation of the expected result. These calculation codes should be verified against suitable measurements. We performed simulations and measurements to validate calculation of the film response in the presence of target motion.MethodsAll calculations were performed with GSI's treatment planning system TRiP. Interplay patterns between scanned particle beams and moving film detectors are very sensitive to slight deviations of the assumed motion parameters and therefore ideally suited to validate 4D calculations. In total, 14 film motion parameter combinations with lateral motion amplitudes of 8, 15, and 20 mm and 4 combinations for lateral motion including range changes were used. Experimental and calculated film responses were compared by relative difference, mean deviation in two regions-of-interest, as well as line profiles.ResultsIrradiations of stationary films resulted in a mean relative difference of -1.52% ± 2.06% of measured and calculated responses. In comparison to this reference result, measurements with translational film motion resulted in a mean difference of -0.92% ± 1.30%. In case of irradiations incorporating range changes with a stack of 5 films as detector the deviations increased to -6.4 ± 2.6% (-10.3 ± 9.0% if film in distal fall-off is included) in comparison to -3.6% ± 2.5% (-13.5% ± 19.9% including the distal film) for the stationary irradiation. Furthermore, the comparison of line profiles of 4D calculations and experimental data showed only slight deviations at the borders of the irradiated area. The comparisons of pure lateral motion were used to determine the number of motion states that are required for 4D calculations depending on the motion amplitude. 6 motion states per 10 mm motion amplitude are sufficient to calculate the film response in the presence of motion.ConclusionsBy comparison to experimental data, the 4D extension of GSI's treatment planning system TRiP has been successfully validated for film response calculations in the presence of target motion within the accuracy limitation given by film-based dosimetry.

Highlights

  • Treatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D)

  • Apart from comparing measured with calculated results that will validate the calculation we studied the impact of the number of motion states used for 4D calculation on the precision of the calculation in dependence on the motion amplitude

  • Film response calibration For the experiments without absorbers, analysis of the film response in dependence on the deposited dose resulted in a slope m of the blackening curve of mC-12, E = 272 MeV/u = 0.33/Gy with a fitting error of Δm = 0.0125/Gy

Read more

Summary

Introduction

Treatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D). Part of 4D treatment planning is calculation of the expected result. These calculation codes should be verified against suitable measurements. Our treatment planning system for scanned particle beams (Treatment planning for Particles, TRiP) [1] was extended to include 4D functionality, i.e. time resolved dose calculation and treatment plan optimization [2]. The purpose of this contribution is to report measurements and corresponding

Methods
Results
Conclusion