Abstract

Rescue stations are usually provided in very long railway tunnels. Those stations already constructed or under construction worldwide are reviewed and the basic pattern of smoke control during a rescue station fire is identified. A total of 54 model scale tests were carried out to investigate smoke control issues in rescue station fires. The effects of heat release rate, train obstruction, fire source location and ventilation condition on smoke control in the cross-passages of a rescue station were tested and analyzed. A critical smoke layer temperature near the fireproof door protecting the rescue station was investigated theoretically and experimentally and a simple equation for this temperature is obtained. A height of 2.2 m is proposed for the fireproof doors in cross-passages of rescue stations. Language: en

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.