Abstract

The purpose of this study is to compare the difference of results between two methods of femoral box osteotomy adopted by two designs of posterior stabilized total knee prostheses. Retrospective analysis of the results of two groups of patients operatedupon using two primary PS TKA systems, PFC Sigma (DePuy Synthes, Johnson and Johnson®) and Genesis II prosthesis (Smith and Nephew®), with an average of fiveyear follow-up was done. Group 1 included 152 knees in 121 patients and group 2 included 122 knees in 111 patients. The average follow-up period in both groups was fiveyears. The box osteotomy method depends on bone saw in group 1, and bone reamer in group 2. The KSS score of group 2 was better in the first sixmonths postoperatively. Then, no significant differences were seen in the remaining follow-up visits. The risk of periprosthetic fractures was significantly higher in group 1 (p-value 0.040). Survival analysis showed a significantly shorter time for reoperation in group 1 than in group 2 as described by log-rank test, (p < 0.006). The method of box cutting has an impact on the function and longevity of posterior stabilized primary knee implants. The risk of periprosthetic fractures can be reduced by proper patient selection, decreasing the box sizes, and development of more "controlled" box osteotomy instruments.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call