Abstract

The furnace efficiency can be maintained or improved slightly by lowering the excess air ratio and raising the air preheat temperature in the heat furnace. The results obtained with a plant-size industrial furnace show that when the excess air oxygen concentration is reduced from 4% to 3%, the furnace efficiency is raised by 0.6%. However, raising the temperature of the pre-heated air will cause a higher furnace temperature and a faster flowing speed of the air in the furnace. Thus, the heat in the radiation zone of the furnace can be evenly transmitted to shorten the time for the fuel to reach the igniting point, and reduce the heat loss from the hot air stream. This will reduce the emission of CO 2 and NO x. If the temperature of the pre-heated air is raised from 200 °C to 240 °C, about 2.3 × 10 6 m 3 of natural gas can be saved annually to reduce 3.1 × 10 3 t of CO 2 and 14.3% of nitrogen oxide emissions. Such operational adjustments of the furnace using the recovered FG will save energy, reduce CO 2 emission and alleviate the adverse impact to environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.