Abstract

This review of the saturation magnetic recording process is tutorial in approach. The emphasis throughout is on the development of intuitive understanding as well as the development of a first-order analysis (good to 10-20 percent) of the process. By means of treating two different functional approximations to the magnetization distribution in the medium, linear and arctangent, it is shown that the peak output voltage and half-amplitude pulse width of a transition are nearly independent of the distribution. Thus good estimates of these important system parameters may be made without reliance upon a specific model. It is made apparent that head-to-medium spacing and effective-medium thickness are of dominant importance in system density considerations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.