Abstract

The aim of the study was to access the SARS-CoV-2 antibody seroprevalence in healthcare workers (HCWs) of a tertiary pediatric hospital after the first wave of the pandemic and to compare the results among seven commercially available antibody detection assays, including chemiluminescence (CMIA), electroluminescence (ECLIA), Εnzyme-Linked Immunosorbent Assay (ELISA), and rapid immunochromatography (RIC). SARS-CoV-2 antibody detection was performed in serum samples of 1216 HCWs, using a reference CMIA assay and 8/1216 (0.66%) were detected positive. Positive serum samples were further tested with other assays; however, only one sample was positive by all tests. The rest 7 cases were negative with ECLIA and ELISA and gave discordant results with RIC test. Six months later, new serum samples of seropositive HCWs were analyzed with the same 7 tests, with inconsistent results again. Identification of reliable SARS-CoV-2 antibody tests is important to determine the actual number of past infections, the duration of antibodies, and guide public health decisions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.