Abstract

BackgroundThe COVID-19 pandemic affected universities and institutions and caused campus shutdowns with a transition to online teaching models. To detect infections that might spread on campus, we pursued research towards detecting SARS-CoV-2 in air samples inside student dorms. MethodsWe sampled air in 2 large dormitories for 3.5 months and a separate isolation suite containing a student who had tested positive for COVID-19. We developed novel techniques employing 4 methods to collect air samples: Filter Cassettes, Button Sampler, BioSampler, and AerosolSense sampler combined with direct qRT-PCR SARS-CoV-2 analysis. ResultsFor the 2 large dorms with the normal student population, we detected SARS-CoV-2 in 11 samples. When compared with student nasal swab qRT-PCR testing, we detected SARS-CoV-2 in air samples when a PCR positive COVID-19 student was living on the same floor of the sampling location with a detection rate of 75%. For the isolation dorm, we had a 100% SARS-CoV-2 detection rate with AerosolSense sampler. ConclusionsOur data suggest air sampling may be an important SARS-CoV-2 surveillance technique, especially for buildings with congregant living settings (dorms, correctional facilities, barracks). Future building designs and public health policies should consider implementation of Heating, Ventilation, and Air Conditioning surveillance.