Abstract
This paper presents the theory and procedure for designing sampled-data control systems of the rippleless type having a digital processing unit in the forward line and another digital processing unit in the feedback loop to respond optimally to inputs as well as to neutralize the disturbance. Two examples using the proposed design procedure are given, and their root loci are plotted and discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the American Institute of Electrical Engineers, Part II: Applications and Industry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.