Abstract

By using an appropriate in-line sampling system, it is possible to obtain representative samples of ballast water from the main ballast line. An important parameter of the sampling port is its “isokinetic diameter” (DISO), which is the diameter calculated to determine the velocity of water in the sample port relative to the velocity of the water in the main ballast line. The guidance in the U.S. Environmental Technology Verification (ETV) program protocol suggests increasing the diameter from 1.0× DISO (in which velocity in the sample port is equivalent to velocity in the main line) to 1.5–2.0× DISO. In this manner, flow velocity is slowed—and mortality of organisms is theoretically minimized—as water enters the sample port. This report describes field and laboratory trials, as well as computational fluid dynamics modeling, to refine this guidance. From this work, a DISO of 1.0–2.0× (smaller diameter sample ports) is recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.