Abstract

There are a number of factors that affect the quality control of an osmotic product. One of these is the concentration of the osmotic solution. There are several ways to measure solution concentration, such as optical measurement method, freezing point temperature measurement method, wave principle measurement method, viscosity and specific gravity measurement method. Saline solution concentration of the osmotic solution based on contact angle. The experiments showed whenever the saline solution concentration increased, the contact angle measured on the acrylic substrate increased as well. Their relation is also the linear correlation. Lastly, the developed software evaluated the saline solution concentration based on the contact angle close to the prepared saline solution concentration. The measured concentration was linear correlation with R-squared value of 0.996 that can be accurately applied on concentrations of 5% to 30% with maximum error of 4.72%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.