Abstract
In the last experimental campaign (OP1.2b: 7/2018 to 10/2018) of the Wendelstein 7-X stellarator (W7-X), the first of two neutral beam injectors (NBI) was commissioned with 2 plasma sources. The safe operation of the NBI requires the exclusion of hazards to personnel and minimization of system hazards. The NBIcontrol system consists of a standard PLC based on PCS7 from Siemens AG and a separate safety controller based on PNOZmulti from Pilz GmbH. The requirements of the NBI safety control are derived from an analysis of the specific personal and plant hazards in accordance with the international standards IEC 61508 / IEC61511. Particular challenges are the usage of high voltage, open high frequency and high power sub systems, and explosive gases that are distributed over different locations. Firstly, the paper describes the procedure followed by the hazard assessment and for determining solutions for safe operation. Secondly, the paper, describes the hardware structure of the NBI safety system. Lastly details of individual technical solutions, e.g. for access to the high voltage area of the NBI injector, are described.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.